|
Articles in Journals, Books, and Book Chapters, 2013
Causey, M.W., A. Jayaraj, D.F. Leotta, M. Paun, K.W. Beach, T.R. Kohler, E.R. Zierler, and B.W. Starnes, "Three-dimensional ultrasonography measurements after endovascular aneurysm repair," Ann. Vascular Surg., 27, 146-153, doi:10.1016/j.avsg.2012.01.018, 2013. Link
Chan, L.W., Y.-N. Wang, L.Y. Lin, M.P. Upton, J.H. Hwang, and S.H. Pun, "Synthesis and characterization of anti-EGFR fluorescent nanoparticles for optical molecular imaging," Bioconjugate Chem., 24, 167-175, doi:10.1021/bc300355y, 2013. Link
Dunmire, B., J.C. Kucewicz, S.B. Mitchell, L.A. Crum, and K.M Sekins, "Characterizing an Agar/Gelatin phantom for image guided dosing and feeback control of high-intensity focused ultrasound," Ultrasound Med. Biol., 39, 300-311, 2013. Link
Garcia J.D., M. Gofeld, R.P. Illian, J.D. Loeser, M. Kliot, A.M. McClintic, A. Ward, A. Yao, and P.D. Mourad, "Intense focused ultrasound as a potential research tool for the quantification of diurnal inflammatory pain," Ultrasonics, 53, 84-89, doi:10.1016/j.ultras.2012.04.002, 2013. Link
Harper, J.D., M.D. Sorensen, B.W. Cunitz, Y.-N. Wang, J.C. Simon, F. Starr, M. Paun, B. Dunmire, H.D. Liggitt, A.P. Evan, J.A. McAteer, R.S. Hsi, and M.R. Bailey, "Focused ultrasound to expel calculi from the kidney: Safety and efficacy of a clinical prototype device," J. Urol., EOR, doi:10.1016/j.juro.2013.03.120, 2013. Link
Li, Q., T.J. Matula, J. Tu, X. Guo, and D. Zhang, "Modeling complicated rheological behaviors in encapsulating shells of lipid-coated microbubbles accounting for nonlinear changes of both shell viscosity and elasticity," Phys. Med. Biol., 58, 985-998, doi:10.1088/0031-9155/58/4/985, 2013. Link
Lu, W., O.A. Sapozhnikov, M.R. Bailey, P.J. Kaczkowski, and L.A. Crum, "Evidence for trapped surface bubbles as the cause for the twinkling artifact in ultrasound imaging," Ultrasound Med. Biol., EOR, doi:10.1016/j.ultrasmedbio.2013.01.011, 2013. Link
Marzban, C., P.R. Illian, D. Morison, A. Moore, M. Kliot, M. Czosnyka, and P.D. Mourad, "A method for estimating zero-flow pressure and intracranial pressure," J. Neurosurg. Anesthesiol.,25, 25-32, doi:10.1097/ANA.0b013e318263c295, 2013. Link
McClintic, A.M., T.C. Dickey, M. Gofeld, M. Kliot, J.D. Loeser, P. Richebe, and P.D. Mourad, "Intense focused ultrasound preferentially stimulates subcutaneous and focal neuropathic tissue: Preliminary results," Pain Med., 14, 84-92, doi:10.1111/j.1526-4637.2012.01510.x, 2013. Link
McGah, P.M., D.F. Leotta, K.W. Beach, R. Eugene Zierler, and A. Aliseda, "Incomplete restoration of homeostatic shear stress within arteriovenous fistulae," J. Biomech. Eng., 135, doi:10.1115/1.4023133, 2013. Link
Pillonetto, G., B.M. Bell, and S. Del Favero, "Distributed Kalman smoothing in static Bayesian networks," Automatica, 49, 1001-1011, doi:10.1016/j.automatica.2013.01.016, 2013. Link
Sapozhnikov, O., and M.R. Bailey, "Radiation force of an arbitrary acoustic beam on an elastic sphere in a fluid," J. Acoust. Soc. Am., 133, 661-676, doi:10.1121/1.4773924, 2013. Link
Sorensen, M.D., J.D. Harper, R.S. Hsi, A.R. Shah, M.K. Dighe, S.J. Carter, M. Moshiri, M. Paun, W. Lu, and M.R. Bailey, "B-mode ultrasound versus color Doppler twinkling artifact in detecting kidney stones," J. Endourol., 27, 149-153, doi:10.1089/end.2012.0430, 2013. Link
Tych, R.E., M. Gofeld, J.G. Jarvik, M. Kliot, J.D. Loeser, A.M. McClintic, R.J. Ollos, K.D. Pederson, R.E. Sparks, G.W. Terman, and P.D. Mourad, "Neuropathic tissue responds preferentially to stimulation by intense focused ultrasound," Ultrasound Med. Biol., 39, 111-116, doi:10.1016/j.ultrasmedbio.2012.08.012, 2013. Link
Wang, Y.-N., T. Khokhlova, M. Bailey, J.H. Hwang, and V. Khokhlova, "Histological and biochemical analysis of mechanical and thermal bioeffects in boiling histotripsy lesions induced by high intensity focused ultrasound," Ultrasound Med. Biol., 39, 424-438, doi:10.1016/j.ultrasmedbio.2012.10.012, 2013. Link
Xu, Z.S., R.J. Lee, S.S. Chu, A. Yao, M.K. Paun, S.P. Murphy, and P.D. Mourad, "Evidence of changes in brain tissue stiffness after ischemic stroke derived from ultrasound-based elastography," J. Ultrasound Med., 32, 485-494, 2013. Link
|